Wiring 120v Circuit Breaker
Wire gauge refers the physical size of the wire rated with a numerical designation that runs opposite to the diameter of the conductorsin other words the smaller the wire gauge number the larger the wire diameter.
Wiring 120v circuit breaker. If 3 wire romex is used as a branch circuit to supply two 120v circuits black red and white wire a two pole breaker must be used so all ungrounded wires in the multi wire branch circuit are disconnected simultaneously. This breaker looks like two standard breakers stacked on top of each other and therefore requires that two breaker positions be open. A 120 volt circuit has only one hot wire connected to the breaker plus a neutral wire connected to the neutral bus bar in the service panel. Wiring a gfci circuit breaker.
How to wire a simple 120v electrical circuit. Use a 15 amp breaker with 14 gauge wire and a 20 amp breaker with 12 gauge wire. Wires come into the box from locations throughout the house. Wire a gfci circuit breaker.
Breaker boxes are also called subpanels. Common sizes include 14 12 10 8 6 and 2 gauge wire. They consist of ground and neutral bus bars and space for several circuit breakers. The wires are run in conduit attached to the box or are in nonmetallic cable.
In some circumstances a 120v circuit requires a double pole breaker. If youre adding a 120240 volt circuit strip away a inch of insulation from the red hot wire as well. Insert the end of the hot wire into the terminal on the new circuit breaker and tighten the setscrew. This kind of circuit is used for dishwashers whirlpool spas and other locations where water contact is likely.
This 20 amp 120 volt breaker is a form of gfci that can be installed at the circuit source. Each 240v circuit has two hot wires as opposed to only one. Turn off the main breaker in the service panel and remove the panel cover. While the breaker provides this higher voltage it operates as two linked 120v circuits.
Running a wire from a new breaker in the breaker panel to a workshop area in the basement for a 240 volt circuit for my table saw and bandsaw httpwoodgear. Hiring an electrician is usually the best way to go where 120 volt circuits are concerned but if you are up to it you might save money by doing some basic electrical work yourself. This diagram illustrates wiring for a circuit breaker with a built in ground fault circuit interrupter or gfci. Check the circuits with your voltage tester to make sure that they are not hot.
Wire is sized by the american wire gauge awg system. Verify that the gfci breaker matches the circuit wiring.